Plant hire company fined after worker fatally injured

246

Plant hire company, Ruislip Plant has been fined £99,000 after a worker was fatally injured whilst undertaking maintenance at a construction site in West Street, Maidenhead

Reading Crown Court heard that, on 13 May 2014, Ben Wylie, was assisting the Ruislip Plant Ltd director Noel Kearney (since deceased) with the maintenance of a high-pressure grease track adjusting mechanism at a construction site in West Street, Maidenhead.

During the process, the grease nipple assembly and a stream of high-pressure grease was forcibly ejected from the mechanism and struck Ben Wylie in the shoulder and chest causing fatal injuries.

HSE investigation

An investigation by the Health and Safety Executive (HSE) found that the components had been forcibly ejected on the previous day and had sustained damage in that event, reducing the pressure at which it would subsequently fail.

Once the fitting had been ejected, it should not have been refitted. Despite the fittings having been previously ejected and damaged, Kearney attempted to modify and refit the grease nipple and adaptor to the high-pressure system.

He then began to re-pressurise the tracks by pumping in grease using a hand-operated grease gun. The pressure built in the system and at a critical point the damaged and modified components were again ejected. A pressure test with all suitable safeguards was required in these circumstances but there was no safe system of work during which resulted in the modifications to the grease gun bringing Ben Wylie into the danger zone.

Ruislip Plant Ltd pleaded guilty to breaching Section 3(1) of the Health & Safety at Work etc. Act 1974. The company has been fined £99,000 and ordered to pay costs of £116, 973.36.

‘Safety procedure was not adhered to’

After the hearing, HSE inspector John Glynn, said: “HSE guidance is very specific on how this work should be undertaken and previously ejected or damaged parts must not be reused as they were in this case.

“This incident could have been avoided if Ruislip Plant Ltd had instead undertaken a risk assessment and devised a safe system of work. That safe system of work would necessarily have ensured that new parts were used, and that the safety procedure of a pressure test was performed.

“However, a new component was not used in this incident and the safety procedure was not adhered to.

“That failure to adhere to the correct procedure for pressure testing was directly causative of this incident. No control measures were put in place by Ruislip Plant Limited and that sadly led to the death of Ben Wylie.”

Editor's Picks

LEAVE A REPLY

Please enter your comment!
Please enter your name here